What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO RH WING LOWER FALSE SPAR AFT OF MLG TRUNION AT STA XW75, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 51-1-20D, DWG 9887427.