What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO SEAT TRACK AT STA 1577-1600 AND RBL45, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-3 FIG8A, 51-3-0. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).