What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO ANTENNA PAD AT STA 87-93 AND L36, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-11, 51-3-0.