What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO CUSP ANGLE AT STA 437, X=62, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 51-3-0. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).