What was found
DURING A MAINTENANCE VISIT FOUND MISSDRILLED DAMAGE TO FWD CARGO PIT FRAME AT STA.380 AND L32L, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 51-1-21, 53-2-0 FIG 2.