What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FWD CARGO PIT CROSS SLIDE DOOR JAMB BACK UP FITTING NR 1 LWR TEE BOLT, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-0 FIG2D, 51-1-21.