What was found
DURING A MAINTENANCE VISIT FOUND DRILL DAMAGE TO MCD JAMB DOOR FRAME AT STA330 AND L17L-L21L, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DHSK 996-743.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A MAINTENANCE VISIT FOUND DRILL DAMAGE TO MCD JAMB DOOR FRAME AT STA330 AND L17L-L21L, DAMAGE EXCEEDED LIMITATION IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DHSK 996-743.