What was found
DURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO R/H WING O/B L/E RIBS AT STA. XFS672.5-678.5, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. NDT HFCC INSP IAW SPM06-10-01.001. FABRICATED PART AND INSTALLED IAW DC-8 SRM 57-2-0 FIG.2, 51-1-20D.