What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO C-PIT ANGLE AT STA.1220-1228 AND L27R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 51-1-20D AND DWG#9754947. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).