What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO B-PIT TORQUE BOX WEB AT STA515-520, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-4, 51-1-20D AND DWG#5616520. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).