What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO FRAME AT STA.1100 AND L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-20A&D, 51-1-21, AND DWG#5764343. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).