What was found
DURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO 4 INTERCOSTALS AT STA.970-980 AND RBL48-55 AND R/H W/W AFT FRAME, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-1-0, 51-1-21, 51-1-21A. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).