What was found
KMCN - DURING C-CHECK, FOUND FLOOR BEAM TO CUSP ATTACH BRACKET CRACKED AT FS 1220, RIGHT SIDE. MAINTENANCE REMOVED AND FABRICATED NEW FITTING IAW DER APPROVED COTNEY ENGINEERING SKETCH A27-D01. INSTALLED IAW DC8-SRM 53-1-0. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
KMCN - DURING C-CHECK, FOUND FLOOR BEAM TO CUSP ATTACH BRACKET CRACKED AT FS 1220, RIGHT SIDE. MAINTENANCE REMOVED AND FABRICATED NEW FITTING IAW DER APPROVED COTNEY ENGINEERING SKETCH A27-D01. INSTALLED IAW DC8-SRM 53-1-0. (M)