What was found
DURING C-CHECK, FOUND 2 HOLES DRILLED IN FRAME INBD FLANGE 3 AND 12 ABOVE FLOOR IN UPPER CARGO COMPARTMENT, Y=440, LT SIDE. FABRICATED REPAIR ANGLE IAW DER APPROVED ENGINEERING SKETCH A98-R03. DRILLED, TREATED, PRIMED AND INSTALLED IAW DC-8 SRM 51-1-20D.