What was found
DURING C-CHECK, FOUND TEMPORARY REPAIR ON LT HORIZ STAB LEADING EDGE, O/B SECTION. REMOVED TEMPORARY REPAIR, FABRICATED INTERNAL AND EXTERNAL DOUBLERS AND STRAPS IAW DER APPROVED ENGINEERING SKETCH A98-R14, INSTALLED IAW DC-8 SRM 51-1-20D, 51-1-21.