What was found
DURING A MAINTENANCE VISIT, FOUND EXFOLIATION CORROSION DAMAGE TO LONGERON 21R PAST LIMITATIONS IAW DC-8 SRM, AT Y=1640. INSTALLED REPAIR IAW DER APPROVED ENGINEERING SKETCH B21-11, TREATED AREA IAW DC-8 SRM 51-1-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A MAINTENANCE VISIT, FOUND EXFOLIATION CORROSION DAMAGE TO LONGERON 21R PAST LIMITATIONS IAW DC-8 SRM, AT Y=1640. INSTALLED REPAIR IAW DER APPROVED ENGINEERING SKETCH B21-11, TREATED AREA IAW DC-8 SRM 51-1-8.