What was found
DURING MAINTENANCE VISIT, FOUND DOOR JAMB (P/N 9779454) CORRODED PAST LIMITATIONS IAW DC-8 SRM, AT Y=333 AND BETWEEN LONGERONS L35L TO L35R. FABRICATED AND INSTALLED FILLER FROM 7075, 2 EACH REINFORCEMENT ANGLES FROM .080 7075T-0 HEAT-TREATED TO T-6. ALL WORK ACCOMPLISHED IAW FAA-DER APPROVED REO-02575.