What was found
DURING A MAINTENANCE VISIT, FOUND MISDRILLED HOLES IN FRAME, AT Y=280 LT AND GUSSET. FABRICATED AND INSTALLED REPAIR ANGLE, 4 CLIPS AND 5 GUSSETS IAW DER APPROVED ENGINEERING SKETCH C44-R28. TREATED AREA IAW DC-8 SRM 51-1-8 AND 51-1-20B.