As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING A MAINTENANCE VISIT, FOUND LOWER AFT LEG OF TRANSVERSE FLOORBEAM SUPPORT CORRODED BEYOND LIMITATIONS, AT Y=902 AND X=-20 TO X-50. REMOVED CORROSION AND TREATED IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED SHIM AND STRAP REPAIR IAW DER APPROVED COTNEY ENGINEERING SKETCH C44-R25.