What was found
DURING A MAINTENANCE VISIT, FOUND INNER SKIN DENTED BEYOND LIMITS IAW DC-8 SRM, AT Y=1240 AND BETWEEN LONGERONS 34R AND 36. REMOVED DAMAGED SECTION, FABRICATED AND INSTALLED FILLER AND DOUBLER REPAIR IAW DER APPROVED ENGINEERING SKETCH C44-R42.