What was found
DURING A MAINTENANCE VISIT, FOUND FLOORBEAM CORRODED PAST LIMITS IAW DC-8 SRM, AT Y=1440 AND X=-10.5. REMOVED AND TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DER APPROVED ENGINEERING SKETCH C44-R13.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A MAINTENANCE VISIT, FOUND FLOORBEAM CORRODED PAST LIMITS IAW DC-8 SRM, AT Y=1440 AND X=-10.5. REMOVED AND TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW DER APPROVED ENGINEERING SKETCH C44-R13.