SDR RRXA97242

Service difficulty report · Fire Warning · Doug DC863F

Difficulty date
August 28, 1997
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N865F
Make and model
Doug DC863F
Aircraft serial
46088
Part
Fire Warning
Condition
Malfunctioned
Location
Nr 2 Engine
Stage of operation
CR
Nature of condition
N
Precautionary procedure
H

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

INTERMITTENT FIRE WARNING ON NR 2 ENG. SHUT BLEED AIR OFF ON NR 2, NO FURTHER WARNINGS, FIRE WARNING TEST GOOD. COULD NOT DUPLICATE PROBLEM. TIGHTENED PNUE CLAPS ON NR 2 PNUE PRESSURE REG, NO OTHER DEFECTS NOTED. ON GROUND RUN NR 2 ENG FIRE WARNING OPS CHECK GOOD. NR 2 ENG PNEU BLEED SYSTEM OPS CHECKS GOOD AND LEAK CHECKS GOOD.