What was found
DURING A MAINTENANCE VISIT, FOUND FRAME CRACKED IN WEB AT DOOR BAYONET FITTING AT, STA 62.25 LEFT SIDE. *S/D* REMOVED DAMAGED SECTION, FABRICATED AND INSTALLED 2 DOUBLERS REPAIRS IAW DAC DWG 5597646 AND FAA DER APPROVED ENGINEERING SKETCH REO-03655.