What was found
DURING A MAINTENANCE VISIT, FOUND NR 1 CARGO PIT DOOR JAMB DAMAGED AT UPPER CORNER, TANGENT IN A DIFFERENT LOCATION OTHER THAN SHOWN IAW DC-8 SRM 53-2-0, FIGURE 22 SHEET 3. *S/D* REPAIRED DOOR JAMB IAW FAA DER APPROVED TIMCO ENGINEERING SKETCH REO-03672 REV A, AND DC-8 SRM 53-2-0 FIGURE 22. ALSO, TREATED AND PRIMED AREA IAW SRM 51-1-8.