What was found
PERFORMED FOLLOW-UP INSPECTION OF FLOORBEAM AT STA 1360 AND BL 58RT, FOUND CORROSION DAMAGE BEYOND LIMITATIONS IAW DC-8 SRM. REMOVED CORROSION DAMAGE, FABRICATED AND INSTALLED REPAIR FILLERS AND ANGLES IAW FAA APPROVED DER COTNEY ENGINEERING SKETCH D19-R01 AND DC-8 SRM 51-1-8 AND 51-1-21.