What was found
DURING A MAINTENANCE VISIT, FOUND FLOORBEAM CORRODED BEYOND LIMITATIONS IAW DC-8 SRM AT STA 920.57 LEFT. FABRICATED AND INSTALLED REPAIR ANGLE IAW FAA APPROVED COTNEY ENGINEERING SKETCH D02-R04. TREATED AREA IAW DC-8 SRM 51-1-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING A MAINTENANCE VISIT, FOUND FLOORBEAM CORRODED BEYOND LIMITATIONS IAW DC-8 SRM AT STA 920.57 LEFT. FABRICATED AND INSTALLED REPAIR ANGLE IAW FAA APPROVED COTNEY ENGINEERING SKETCH D02-R04. TREATED AREA IAW DC-8 SRM 51-1-8.