DURING A MAINTENANCE VISIT, FOUND CARGO DOOR JAMB WITH PREVIOUS REPAIR IN PSE AREA THAT IS NOT APPROVED, AT STA 520 LOWER JAMB AREA. REMOVED PREVIOUS REPAIR, CUT OUT DAMAGE SECTION. FABRICATED AND INSTALLED REPAIR DOUBLER IAW DC-8 SRM 53-2-0 FIGURE 4, AND 52-4-1 FIGURE 2 AND 51-9-0 FIGURE 68A. TREATED AREA IAW DC-8 SRM 51-1-8.