What was found
DURING A MAINTENANCE VISIT, FOUND FRAMES WITH MISS-DRILLED HOLES, AT STA 190 ALSO STA 200, BETWEEN LONGERONS 7 RIGHT TO 16 RIGHT AND LONGERON 6 LEFT. REMOVED DAMAGED SECTIONS, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR STRAPS IAW FAA APPROVED TIMCO DER ENGINEERING SKETCH REO-04725.