What was found
DURING A MAINTENANCE VISIT, FOUND RIGHT WING, AFT SPAR CAP WITH CORROSION BEYOND LIMITS IAW DC-8 SRM, AT STA 63. REMOVED DAMAGED SECTION, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW FAA APPROVED TIMCO DER ENGINEERING SKETCH REO-04804.