What was found
DURING A MAINTENANCE VISIT, FOUND AFT ENTERANCE DOOR SKIN WITH CRACK BEYOND LIMITS IAW DC-8 SRM, AT STA 1640. REMOVED DAMAGED SECTION, TREATED AREA IAW DC-8 SRM. FABRICATED AND INSTALLED REPAIR IAW FAA APPROVED TIMCO DER ENGINEERING SKETCH REO-04857.