What was found
DURING A MAINTENANCE VISIT, FOUND CROSS SLIDE DOOR, COVER ATTACH ANGLE WITH CORROSION BEYOND LIMITS IAW DC-8 SRM, AT STA 280 BETWEEN LONGERONS 27 RIGHT AND 36. REMOVED DAMAGED SECTION, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW FAA APPROVED TIMCO DER ENGINEERING SKETCH REO-04758.