What was found
DURING A MAINTENANCE VISIT, FOUND BELLY SKIN WITH CORROSION DAMAGE BEYOND LIMITS IAW DC-8 SRM, AT STA 1890 BETWEEN LONGERONS 36 TO 32 RIGHT. REMOVED CORROSION DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED DER TIMCO ENGINEERING SKETCH REO-05195.