DURING A MAINTENANCE VISIT, FITTING (P/N 5615040-2), AT STA 980 AND LONGERON 22 RIGHT FOUND DAMAGED. REMOVED FITTING, FABRICATED NEW FITTING BY MATERIAL SUBSTITUTION. ORIGINAL MATERIAL 7075-T411, SUBSTITIUTED WITH 7075T-T6 IAW FAA APPROVED TIMCO ENGINEERING SKETCH REO-05079. FABRICATED AND INSTALLED NEW FITTING IAW DWG 56150T0 AND DWG 5615041 AND DPS4.999.