What was found
DURING A MAINTENANCE VISIT, FITTING (P/N 3616944-2), AT STA 832 AND LONGERON 21 RIGHT FOUND DAMAGED. REMOVED FITTING, FABRICATED NEW FITTING BY MATERIAL SUBSTITUTION. ORIGINAL MATERIAL 7075-T411, SUBSTITUTED WITH 7075T-T6 IAW FAA APPROVED TIMCO ENGINEERING SKETCH REO-05130. FABRICATED AND INSTALLED NEW FIITING IAW DWG 3616944-2 AND DPS4.999.