What was found
DURING A MAINTENANCE VISIT, FITTING (P/N 3755840-1), AT STA 834 AND LONGERON 21 RIGHT FOUND DAMAGED. REMOVED FITTING, FABRICATED NEW FITTING BY MATERIAL SUBSTITUTION. ORIGINAL MATERIAL 7075-T411, SUBSTITUTED WITH 7075T-T6 IAW FAA APPROVED TIMCO ENGINEERING SKETCH REO-05192. FABRICATED AND INSTALLED NEW FIITING IAW DWG 5615040 AND DPS4.999.