What was found
DURING A MAINTENANCE VISIT, FITTING (P/N 5616132-2), AT WHEEL WELL AND LONGERON 24 RIGHT FOUND DAMAGED. REMOVED FITTING, FABRICATED NEW FITTING BY MATERIAL SUBSTITUTION. ORIGINAL MATERIAL 7075-T411, SUBSTITUTED WITH 7075T-T6 IAW FAA APPROVED TIMCO ENGINEERING SKETCH REO-05079. FABRICATED AND INSTALLED NEW FITTING IAW DWG 5616132 AND DWG 5616429 AND DPS4.999.