What was found
DURING MAINTENANCE VISIT FOUND ANGLE CHAFED EXCEEDING ALLOWABLE LIMITS ON LEFT WING INBOARD T/E STRUCTURE AT WING STA XWS-12. REPLACED ANGLE IAW FAA DER APPROVED TIMCO ENGINEERING SKETCH REO-05479 AND AREA TREATED IAW DC-8 SRM 51-1-8.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING MAINTENANCE VISIT FOUND ANGLE CHAFED EXCEEDING ALLOWABLE LIMITS ON LEFT WING INBOARD T/E STRUCTURE AT WING STA XWS-12. REPLACED ANGLE IAW FAA DER APPROVED TIMCO ENGINEERING SKETCH REO-05479 AND AREA TREATED IAW DC-8 SRM 51-1-8.