What was found
DURING MAINTENANCE VISIT, FOUND FRAME FS 940 WITH MISDRILLED HOLES AT VERIOUS LOCATIONS. REMOVED DAMAGED AREAS, TREATED AREA IAW DC-8 SRM 51-1-8, FABRICATED AND INSTALLED REPAIR ANGLES AND STRAPS IAW FAA DER APPROVED TIMCO SKETCH REO-05618.