What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION, FUSELAGE, FRAME TO MEMBRANE ATTACH ANGLE AT STA 1540 LONGERON 21 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. RECEIVED NEW AND INSTALLED ATTACH ANGLE IAW DC8 SRM 53-2-0. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).