What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION, FUSELAGE, SPAR CAP, AT STA 857, BETWEEN BL 13 RIGHT AND BL 18 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED ANGLE IAW DC8 SRM 53-2-5 FIG 16, 51-1-20D, 51-3-0, AND 51-1-21. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).