What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION, CENTER FUSELAGE, BILGE CORROSION FRAME AT STA 1040 BETWEEN LONGERONS 28 LEFT AND LONGERON 33 LEFT AT NUT PLATES. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED FILLER AND DOUBLER IAW DC8 SRM 53-2-0. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).