What was found
DURING A MAINTENANCE VISIT, FOUND CORROSION, CENTER FUSELAGE, CUSP ANGLE, LT, AT STA 1620, L2 DOOR FRAME FITTING AND LONGITUDIAL ANGLE. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED L2 DOOR FRAME FITTING IAW DC8 SRM 51-1-3, 51-3-2, AND 51-1-20D. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).