DURING A MAINTENANCE VISIT, FOUND CORROSION, FUSELAGE, FORWARD HORIZONTAL FLANGE OF THE FITTING AT FS 1151, LONGERON 32 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR ANGLE AND DOUBLER IAW FAA APPROVED TIMCO DER ENGINEERING SKETCH NR REO- 06124. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).