What was found
DURING A MAINTENANCE VISIT, FOUND ATTACH FITTING WORN, RT I/B FLAP I/B ATTACH FITTING WORN AREA IS GREATER THAN 20 PERCENT OF THE MATERIAL THICKNESS. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW FAA APPROVED TIMCO DER ENGINEERING SKETCH NR REO- 06133.