What was found
DURING A MAINTENANCE VISIT, FOUND DOUBLE DRILLED, FUSELAGE, FLOORBEAM SUPPORT AT STA 380. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR ANGLE AND DOUBLERS IAW FAA APPROVED TIMCO DER ENGINEERING SKETCH NR REO- 06180.