What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, FRAME, AT STA 360, AFT SIDE ABOVE LONGERONS 31 RIGHT AND LONGERON 29 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR ANGLE IAW FAA APPROVED TENNESSEE TECH SERVICES DER ENGINEERING SKETCH NR EO- 99-085 WITH APPROVED 8110-3, DATED MAY 21, 1999. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).