What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, RT UPPER CUSP FRAME 560 AT STA 560 ATTACH ANGLE. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. REMOVED AND REPLACED ATTACH ANGLE IAW DC8 SRM 51-1-21 AND 51-1-8. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).