What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, SKIN, JUST FWD OF TAIL SKID AT STA 1746, LONGERON 36. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED FILLER AND DOUBLER IAW DC8 SRM 53-2-1, INSTALLED FILLER AND DOUBLER IAW DC8 SRM 51-1-21 AND 51-1-22. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).