What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, CABIN FLOOR TRACK AT BL 44 LEFT, BETWEEN STA 240 AND STA 329. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).