What was found
DURING A MAINTENANCE VISIT FOUND CORROSION, FUSELAGE, ATTACH ANGLE, RT W/W AT STA 879, BL 0, WL 16 RIGHT. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGED, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED NEW ANGLE IAW DC8 SRM 51-1-4 (PAGE 1); FABRICATED AND INSTALLED 2 EACH SHIMS WITH BRACKET IAW DC8 SRM 51-1-2 AND 51-1-20 (PAGE 1). (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM).